The operation the reactor at the low power level with a small reactivity margin was accompanied by unstable core temperature and coolant flow, and possibly by instability neutron flux. The control room received repeated emergency signals the levels in the steam/water separator drums, relief valves opened to relieve excess steam into a turbine condenser, large excursions or variations in the flow rate feed water, and from the neutron power controller. In the period between 00:35 and 00:45, it seems emergency alarm signals concerning thermal-hydraulic parameters were ignored, apparently to preserve the reactor power level. Emergency signals from the Reactor Emergency Protection System (EPS-5) triggered a trip which turned f both turbine-generators.
After a period, a more or less stable state at a power level 200 MW was achieved, and preparation for the experiment continued. As part the test plan, at 1:05 a.m. on 26 April extra water pumps were activated, increasing the water flow. The increased coolant flow rate through the reactor produced an increase in the inlet coolant temperature the reactor core, which now more closely approached the nucleate boiling temperature water, and reducing the safety margin. The flow exceeded the allowed limit at 1:19 a.m. At the same time the extra water flow lowered the overall core temperature and reduced the existing steam voids in the core. Since water also absorbs neutrons (and the higher density liquid water makes it a better absorber than steam), turning on additional pumps decreased the reactor power still further. This prompted the operators to remove the manual control rods further to maintain power.
All these actions led to an extremely unstable reactor configuration. Nearly all the control rods were removed, which would limit the value the safety rods when initially inserted in a scram condition. Further, the reactor coolant had reduced boiling, but had limited margin to boiling, so any power excursion would produce boiling, reducing neutron absorption by the water. The reactor was in an unstable configuration that was clearly outside the safe operating envelope established by the designers.

File information
Filename:321370.jpg
Album name:People & Humanity
Rating (1 votes):55555
Keywords:#chernobyl #legacy #reportage #paul #fusco
Filesize:45 KiB
Date added:Sep 29, 2010
Dimensions:700 x 471 pixels
Displayed:42 times
URL:displayimage.php?pid=321370
Favorites:Add to Favorites